Chapter one
Working beside thatch near Pagham Harbour
With thatch covering many roofs in the parish, a tiled or leaded repair often sits right beside reed or straw.
The Sidlesham Church conservation area appraisal says thatch covers many roofs in the village, and the Victoria County History calls thatched roofs common in the parish. Cottages are walled in flint rubble, colour-washed brick or cobbles, and the appraisal adds that local red clay provided the bricks and the roof tiles. A group of buildings here might therefore hold a thatched cottage, a clay-tiled extension and a brick chimney within a few metres of each other. Every junction between those materials is a place where water can slip through, and the roofs next to the thatch are where our work lies. Sea weather off the harbour tests all of them, driving rain pushing sideways into joints that a sheltered site would never wet. A small leak at a tiled extension can soak the thatch beside it, which is why we trace the source before suggesting a repair.
At a glance
- The appraisal says thatch covers many roofs here
- Local red clay supplied bricks and roof tiles
- Flue clearances grow near thatch

1.1 Where tile meets thatch
A lean-to or extension in tile that butts against a thatched wall needs a flashing dressed up the wall, and a gutter or valley that drains clear of the thatch instead of onto it. Overflow keeps thatch wet, and wet thatch decays. We look at where each outlet discharges, how the lead is dressed (lead is the soft grey sheet metal used for flashings and valleys) and whether the junction can move as two different roofs settle at their own pace. A junction that cannot move is one that cracks, so the detail matters more than the material.

1.2 Chimneys beside straw
Approved Document J gives flue outlet heights for solid fuel appliances, and it asks for larger clearances where a roof is thatched. For a flue breaking out within 600mm of the ridge, the outlet stands at least 600mm above the ridge line, and thatch raises the figures further. Where a cottage has a wood-burner, the stack, the flashing and the flaunching (the mortar crown that seats the pots) are checked against the document before we alter anything. Where a stack leans or its joints have eroded, repointing may be enough; where bricks have spalled, a rebuild may be the right answer, and MyBuilder's typical UK range for chimney repointing is £500 to £2,000. Our chimney repairs page covers stacks in more detail, and photographs of each stack go into your written quote.
Flue outlet clearances, solid fuel appliances
- Flue within 600mm of the ridge
- At least 600mm above the ridge
- Flue elsewhere on the roof
- At least 2300mm horizontally from the roof surface, and either 1000mm above where it meets the roof or as high as the ridge
- Flue near an openable rooflight
- At least 1000mm above the opening
- Thatched roof
- Larger clearances apply
Source: Approved Document J, 2010 edition incorporating 2010, 2013 and 2022 amendments, Diagrams 17 and 18